Standard Model Spec
Applying insights gained from industrial customers, rental companies, public utilities and other end users QAS generators are designed to withstand the most demanding on-site conditions and environments.
Considering their impressive performance at full capacity, the QAS line of generators includes excellent features for noise reduction and environmental protection.
QAS generators are purpose built for quick, easy and safe transport and on-site handling. Built to last, a QAS generator will provide years of dependable service for your electrical power generation needs. All members of the widely appreciated QAS family are intelligent multi-task units managing to power a wide range of electrical equipment in different applications.
Their superior component configuration offers a wide range of control modules, electrical settings and mechanical options, in order to guarantee superior quality at efficient operating costs.
Conceived for 100% prime power operation in the most severe outdoor conditions, ready to work in sensitive areas, QAS generators are designed and configured for safe operation with minimal downtime under any circumstance.
Key Features
- Carefully selected components, accurately developed and tested configuration
- Accurate and stable power regardless of the conditions
- Superior standard configuration and extensive option list
- Ability to power a wide range of applications
- Service efficiency: increased up-time
- Compact and safe concept and sturdy design
- Increased transport efficiency
- Designed and built to last
- Superior resale value / longer life time
- 500 hours service interval and superior accessibility to all service points
PERFORMANCE DATA
Generator | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 2 | QAS 200 Vod Stage 2 |
---|---|---|---|---|---|
Generator Rated speed | QAS 200 Vod Stage 3A rpm | QAS 200 Vod Stage 3A 1500 | QAS 200 Vod Stage 3A 1800 | QAS 200 Vod Stage 2 1500 | QAS 200 Vod Stage 2 1800 |
Generator Rated power factor (lagging) | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 3A 0,8 | QAS 200 Vod Stage 3A 0,8 | QAS 200 Vod Stage 2 0,8 | QAS 200 Vod Stage 2 0,8 |
Generator Rated Prime Power, PRP | QAS 200 Vod Stage 3A kVA | QAS 200 Vod Stage 3A 200 | QAS 200 Vod Stage 3A 225,0 | QAS 200 Vod Stage 2 200 | QAS 200 Vod Stage 2 220,0 |
Generator Rated Prime Power, PRP | QAS 200 Vod Stage 3A kW | QAS 200 Vod Stage 3A 160 | QAS 200 Vod Stage 3A 180,0 | QAS 200 Vod Stage 2 160 | QAS 200 Vod Stage 2 176,0 |
Generator Limited Time Power, ESP (Stand-by) | QAS 200 Vod Stage 3A kVA | QAS 200 Vod Stage 3A 220 | QAS 200 Vod Stage 3A 247,5 | QAS 200 Vod Stage 2 220 | QAS 200 Vod Stage 2 242,0 |
Generator Limited Time Power, ESP (Stand-by) | QAS 200 Vod Stage 3A kW | QAS 200 Vod Stage 3A 176 | QAS 200 Vod Stage 3A 198,0 | QAS 200 Vod Stage 2 176 | QAS 200 Vod Stage 2 193,6 |
Generator Continuous Operation Power, COP (Continuous) | QAS 200 Vod Stage 3A kVA | QAS 200 Vod Stage 3A 140 | QAS 200 Vod Stage 3A 157,5 | QAS 200 Vod Stage 2 140 | QAS 200 Vod Stage 2 154 |
Generator Continuous Operation Power, COP (Continuous) | QAS 200 Vod Stage 3A kW | QAS 200 Vod Stage 3A 112 | QAS 200 Vod Stage 3A 126,0 | QAS 200 Vod Stage 2 112 | QAS 200 Vod Stage 2 123,2 |
Generator Rated voltage (3ph. line to line) | QAS 200 Vod Stage 3A V | QAS 200 Vod Stage 3A 400 | QAS 200 Vod Stage 3A 480 | QAS 200 Vod Stage 2 400 | QAS 200 Vod Stage 2 480 |
Generator Rated voltage (1ph. line to neutral) | QAS 200 Vod Stage 3A V | QAS 200 Vod Stage 3A 230 | QAS 200 Vod Stage 3A 277 | QAS 200 Vod Stage 2 230 | QAS 200 Vod Stage 2 277 |
Generator Rated current 3ph. (PRP) | QAS 200 Vod Stage 3A A | QAS 200 Vod Stage 3A 288,7 | QAS 200 Vod Stage 3A 270,6 | QAS 200 Vod Stage 2 288,7 | QAS 200 Vod Stage 2 264,6 |
Generator Rated current 3ph. (ESP) | QAS 200 Vod Stage 3A A | QAS 200 Vod Stage 3A 317,5 | QAS 200 Vod Stage 3A 297,7 | QAS 200 Vod Stage 2 317,5 | QAS 200 Vod Stage 2 291,1 |
Generator Maximum sound power level (LWA) complies with 2000/14/EC | QAS 200 Vod Stage 3A dB(A) | QAS 200 Vod Stage 3A 97 | QAS 200 Vod Stage 3A 99 | QAS 200 Vod Stage 2 97 | QAS 200 Vod Stage 2 99 |
Generator Maximum sound pressure level (LPA) at 7 m | QAS 200 Vod Stage 3A dB(A) | QAS 200 Vod Stage 3A 69 | QAS 200 Vod Stage 3A 71 | QAS 200 Vod Stage 2 69 | QAS 200 Vod Stage 2 71 |
Generator Coupling engine/alternator | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 3A Direct | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 2 Direct | QAS 200 Vod Stage 2 |
Generator Capacity fuel tank (total) | QAS 200 Vod Stage 3A l | QAS 200 Vod Stage 3A 469 | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 2 469 | QAS 200 Vod Stage 2 |
Generator Fuel tank specifications | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 3A Metal | QAS 200 Vod Stage 3A | QAS 200 Vod Stage 2 Metal | QAS 200 Vod Stage 2 |
Generator Fuel Autonomy at full load (Considering full capacity) | QAS 200 Vod Stage 3A h | QAS 200 Vod Stage 3A 11,3 | QAS 200 Vod Stage 3A 9,6 | QAS 200 Vod Stage 2 11,1 | QAS 200 Vod Stage 2 9,0 |
Generator Single step load acceptance (within G2, acc. ISO 8528-5:1993) | QAS 200 Vod Stage 3A % | QAS 200 Vod Stage 3A 80 | QAS 200 Vod Stage 3A 95 | QAS 200 Vod Stage 2 50 | QAS 200 Vod Stage 2 55 |
Generator Frequency drop (lower than % isochronous) | QAS 200 Vod Stage 3A % | QAS 200 Vod Stage 3A ≤ 0,25 | QAS 200 Vod Stage 3A ≤ 0,25 | QAS 200 Vod Stage 2 ≤ 0,25 | QAS 200 Vod Stage 2 ≤ 0,25 |
Generator Maxim oil consumption 100% load | QAS 200 Vod Stage 3A l/h | QAS 200 Vod Stage 3A 0,08 | QAS 200 Vod Stage 3A 0,09 | QAS 200 Vod Stage 2 0,08 | QAS 200 Vod Stage 2 0,09 |

Manufacturing and Environmental Standards
The QAS range is manufactured following stringent ISO 9001 regulations, and by a fully implemented Environmental Management System fulfilling ISO 14001 requirements.
Attention has been given to ensure minimum negative impact to the environment.
The QAS range complies with the latest noise emission directives.
Declaration of Conformity
Our QAS EC falls under the provisions of the article 12.2 of the EC Directive 2005/42/EC on the approximation of the laws of the Member States relating to machinery, is in conformity with, the relevant Essential Health and Safety Requirements of this directive:
MACHINERY SAFETY (2006/42/EC): EN ISO 12100-1, EN ISO 12100-2, UNE EN 12601
ELECTROMAGNETIC COMPATIBILITY (2004/108/EC): EN 61000-6-5, EN 61000-6-4
LOW VOLTAGE EQUIPMENT (2006/95/EC): EN 60034, EN60204-1, EN 60439
OUTDOOR NOISE EMISSION (2000/14/EC): ISO 3744
IS0 8528: QAS generators are design to comply with ISO 8528 regulation